Omron CX-INTEGRATOR - V2.3 REV 02-2009 Operation Manual page 41

Table of Contents

Advertisement

Files
Controller Link node
files (.crg)
Component
DeviceNet device
parameter files
parameter files
(.dvf)
CompoWay/F
component
parameter files
(.xml)
Data link table files
Controller Link data
link table files (.cl2)
SYSMAC LINK data
link table files (.sl3)
Routing table files
FINS local routing
table files (.rtg, .rxg)
(See note 2.)
FINS network
routing table files
(.rt3, .rx3)
(See note 2.)
Note
With DeviceNet only, the following files can also be exported and saved.
EDS files (.eds)
The device list saved in CSV format (.csv)
The I/O comments saved in CSV format (.csv)
The device parameters of an OMRON DeviceNet Master Unit saved as an Open
Network Controller DRM_UNIT (virtual unit) file
The device parameters of an OMRON DeviceNet Master Unit saved as a NetX Server
(NetX Server for DeviceNet) file
Note
The CX-Integrator does not support files created in the DeviceNet Configurator Ver.
1.0 file format.
Contents
Network configuration for Controller Link networks connected directly to the
target PLC
Parameters for individual DeviceNet devices (master or slave)
Note: These are the same as the DeviceNet device parameter files (.dvf)
created with DeviceNet Configurator version 2.@. Files created with
DeviceNet Configurator version 2.@ can be imported.
Parameters for individual CompoNet devices (master or slaves)
Parameters for individual CompoWay/F slaves (except for Temperature
Controllers)
CPU Unit parameters (parts of PLC Setup: serial communications settings)
Controller Link or SYSMAC LINK network parameters
Controller Link and SYSMAC LINK Unit allocated DM Area words settings,
including automatically set data link parameters
Ethernet Unit CPU Bus Unit System Settings
Serial Communications Board/Unit serial communications settings
Controller Link user-set data link tables
Note: These are the same as the Controller Link data link table files (.cl3)
created with the CX-Net. Files created with the CX-Net can be
imported.
SYSMAC LINK user-set data link tables
Note: These are the same as the SYSMAC LINK data link table files (.sl3)
created with the CX-Net. Files created with the CX-Net can be
imported.
Routing tables of the target PLC
Note 1: These are the same as the FINS local routing table files (.rtg, .rxg)
created with the CX-Net. Files created with the CX-Net can be
imported.
Note 2: Standard number of relay network table entries (20 max.): .rtg
Extended number of relay network table entries (64 max.): .rxg
Routing tables for all PLCs on networks to which the target PLC belongs
Note 1: These are the same as the FINS network routing table files
(.rt3, .rx3) created with the CX-Net. Files created with the CX-Net
can be imported.
Note 2: Standard number of relay network table entries (20 max.): .rt3
Extended number of relay network table entries (64 max.): .rx3
1-2
1-2-2
Files Created by the CX-Integrator
Details
Specifications
1-13