4-3
Manually Setting Data Links
4-3-4
Creating Data Link Tables Offline
Node Editing Window Settings
Set the data link details for each node (i.e., send size, receive size, reception offset) in
the Node Editing Window.
Note: The Node Edit Window appears in table format by default, as shown below. To convert it
(1)
(3)
No.
Name
(1)
Node
(2)
PLC
(3)
Status
(4)
Area 1/Area 2
(5)
Node
(Display only.
Order can be
changed.)
(6)
Link Addr.
(Automatic
display)
(7)
Size
(Setting/Display)
(8)
Offset
(Setting/Display)
(9)
Src. Addr.
(Automatic
display)
(10)
F4: Move Up
Area
F5: Move Down
Area
Note: The areas and start addresses that can be set for Controller Link data link status depend on
the model of CPU Unit. If the start address is not set correctly, a data link table error will occur
and the LNK indicator on the Controller Link Unit will flash. Refer to the Controller Link Unit
Operation Manual for details.
4-18
back into the earlier list format, select View - Show in List.
(2)
(5)
The settings for each active node
shown in the node field to the left are
displayed here.
(4)
(10)
Selects the address of the node to be edited.
The settings for an active node (selected with
The PLC type set by the Datalink Wizard is displayed and can be changed here.
The status memory area and start address set by the Datalink Wizard are displayed and
can be changed here.
The Area 1 and Area 2 classifications and start addresses set by the Datalink Wizard
are displayed and can be changed here.
• Node addresses are displayed from top to bottom, in order of node refreshing at the
local node (in order of allocated node address).
• To change the refresh sequence set by the Datalink Wizard, click either F4: Move Up
Area or F5: Move Down Area in the Function Bar, or press the corresponding Function
key.
• For the local node send area, the start address of the data sent from the local node is
automatically displayed.
• For the receive area from remote nodes, the local node start address for storing data
received from remote nodes is automatically displayed.
• For the local node send area, the send size set by the Datalink Wizard is displayed
and can be changed here.
• For the receive area from remote nodes, the receive size from remote nodes is set
here in word units. (It can only be set here.) The default is the entire send size from
remote nodes.
The reception offset from the source start address displayed at "Src. Addr." is set here.
(The default is 0.)
• For the local node send area, "Send" is automatically displayed.
• For the receive area from a remote node, the remote node's source start address (the
value before the offset) is automatically displayed.
Changes the node refresh sequence.
(6)
(7)
(8)
(9)
Description
) are displayed to the right.