3-2 Setting the Routing Tables
3-2-2 Creating the FINS Local Routing Tables
Input the appropriate settings in the local network tables for PLC2 and PLC3, as
shown below.
Menu Items in the PLC Routing Table Window
Main menu
File
Edit
Options
Help
Note 1: The Enable/Disable function is supported by C-series PLCs (Controller Link) only.
Note 2: This command is supported only when connected to PLC with CS/CJ-series CPU Units
3-14
PLC2
Local Network Table
Unit number
Local network address
4
5
Sub-menu/command
New
Open Local Routing Table File
Save Local Routing Table File
Open Network Routing Table
File
Save Network Routing Table
File
Add Remote Network
Add SIOU
Always On Top
Main View
Zoom Out
Zoom In
Transfer to PLC
Transfer from PLC
Delete Routing Table
Active Routing Table
Deactive Routing Table
Verify Routing Table
Check Routing Table for errors
Automatic Network Search
Switching the target PLC
(See note 2.)
Number of Remote Network:
Standard [20]
Number of Remote Network:
Expanded [64]
Show File Information
Help Topics
About
with unit version 4.0 or later.
Local Network Table
Unit number
1
2
Initializes (clears) the FINS local routing table.
Opens a FINS local routing table file (.rtg, .rxg
extension).
Saves a FINS local routing table file (.rtg, .rxg
extension).
Opens a FINS network routing table file (.rt3, .rx3
extension).
Saves a FINS network routing table file (.rt3, .rx3
extension).
Adds a relay network table.
Adds a local network table.
The PLC Routing Dialog Box will always be
displayed in the front of the windows.
Reduces the Main View display.
Enlarges the Main View display.
Transfers the edited routing tables to the PLC that is
directly connected online.
Reads the edited routing tables from the PLC that is
directly connected online.
Deletes the routing tables in the registered PLC that
is directly connected online.
Enables the routing tables. (See note 1.)
Disables the routing tables. (See note 1.)
Compares the edited routing tables to the routing
tables in the PLC that is directly connected online.
Checks the created routing tables.
(Cannot be used.)
Switches the target PLC to the PLC directly
connected by a serial connection, or a PLC in the
network connected to that PLC.
Sets the maximum number of destination networks to
the standard value of 20.
Sets the maximum number of destination networks to
the extended value of 64.
This command is supported only for CS/CJ-series
CPU Units with unit version 4.0 or later.
Inputs the author, title, and comment information to
be saved in the routing table file.
Displays help.
Displays the Routing Table Component's version
information.
PLC3
Local network address
0
2
Functions