Omron CJ2 CPU UNIT SOFTWARE User Manual page 631

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

Address
Name
Words
Bits
A10130
---
High-speed
and
Counter 1 Range
A10131
Comparison
Condition 1 to 32
In-range Flags
A10132
---
High-speed
and
Counter 2 Range
A10133
Comparison
Condition 1 to 32
In-range Flags
A10134
---
High-speed
and
Counter 3 Range
A10135
Comparison
Condition 1 to 32
In-range Flags
A10136
---
High-speed
and
Counter 0 Ring
A10137
Counter Maxi-
mum Value
A10138
---
High-speed
and
Counter 1 Ring
A10139
Counter Maxi-
mum Value
CJ2 CPU Unit Software User's Manual
Function
These flags indicate whether the PV is within any of the one to 32
ranges when high-speed counter 1 is being operated in range-
comparison mode with upper and lower limits. The In-range
Flags, however, will be ON whenever the comparison value is
within the range regardless of the whether the high-speed counter
is set to execute the interrupt task when the range is entered or
left.
OFF: Not in range, ON: In range
Bits 00 to 15 in the lower word correspond to ranges 1 to 16. Bits
00 to 15 in the upper word correspond to ranges 17 to 32.
These flags indicate whether the PV is within any of the one to 32
ranges when high-speed counter 2 is being operated in range-
comparison mode with upper and lower limits. The In-range
Flags, however, will be ON whenever the comparison value is
within the range regardless of the whether the high-speed counter
is set to execute the interrupt task when the range is entered or
left.
OFF: Not in range, ON: In range
Bits 00 to 15 in the lower word correspond to ranges 1 to 16. Bits
00 to 15 in the upper word correspond to ranges 17 to 32.
These flags indicate whether the PV is within any of the one to 32
ranges when high-speed counter 3 is being operated in range-
comparison mode with upper and lower limits. The In-range
Flags, however, will be ON whenever the comparison value is
within the range regardless of the whether the high-speed counter
is set to execute the interrupt task when the range is entered or
left.
OFF: Not in range, ON: In range
Bits 00 to 15 in the lower word correspond to ranges 1 to 16. Bits
00 to 15 in the upper word correspond to ranges 17 to 32.
Contain the ring counter maximum values when high-speed
counters 0 is used as ring counters. These values are cleared to 0
if Linear Mode is used.
Lower 4 digits: A10136, Upper 4 digits: A10137
Contain the ring counter maximum values when high-speed
counters 1 is used as ring counters. These values are cleared to 0
if Linear Mode is used.
Lower 4 digits: A10138, Upper 4 digits: A10139
Appendices
Status
Write timing/
Status at
after mode
Related flags, set-
startup
change
tings
Cleared
Cleared
• Refreshed each
cycle during over-
seeing process.
• Refreshed when
comparison is
executed for 1 to
32 ranges.
• Refreshed when
PRV(881) instruc-
tion is executed to
read the results of
range compari-
son.
• Refreshed when
INI(880) instruc-
tion is executed to
change PV or ring
counter maxi-
mum value.
• Reset
Cleared
Cleared
• Refreshed each
cycle during over-
seeing process.
• Refreshed when
comparison is
executed for 1 to
32 ranges.
• Refreshed when
PRV(881) instruc-
tion is executed to
read the results of
range compari-
son.
• Refreshed when
INI(880) instruc-
tion is executed to
change PV or ring
counter maxi-
mum value.
• Reset
Cleared
Cleared
• Refreshed each
cycle during over-
seeing process.
• Refreshed when
comparison is
executed for 1 to
32 ranges.
• Refreshed when
PRV(881) instruc-
tion is executed to
read the results of
range compari-
son.
• Refreshed when
INI(880) instruc-
tion is executed to
change PV or ring
counter maxi-
mum value.
• Reset
Cleared
Cleared
Refreshed when
INI(880) instruction
is executed to
change ring counter
maximum value.
Cleared
Cleared
Refreshed when
INI(880) instruction
is executed to
change ring counter
maximum value.
A-147