Omron CJ2 CPU UNIT SOFTWARE User Manual page 597

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

Address
Name
Words
Bits
A200
A200.11
First Cycle Flag
A200.12
Step Flag
A200.14
Task Started
Flag
A200.15
First Task Star-
tup Flag
A201
A201.10
Online Editing
Wait Flag
A201.11
Online Editing
Flag
A202
A202.00
Communications
to
Port Enabled
A202.07
Flags
A202.08
CJ2 Instructions
Enabled Flag
A202.15
Network Com-
munications Port
Allocation
Enabled Flag
CJ2 CPU Unit Software User's Manual
Function
ON for one cycle after PLC operation begins (after the mode is
switched from PROGRAM to RUN or MONITOR, for example).
ON for the first cycle
ON for one cycle when step execution is started with STEP(008).
This flag can be used for initialization processing at the beginning
of a step.
ON for the first cycle after execution of STEP(008).
When a task switches from STANDBY or DISABLED to READY
status, this flag will be turned ON within the task for one cycle
only.
ON: ON for first cycle (including transitions from STANDBY and
DISABLED status)
OFF: Other
The only difference between this flag and A200.15 is that this flag
also turns ON when the task switches from STANDBY to READY
status.
ON when a task is executed for the first time. This flag can be
used to check whether the current task is being executed for the
first time so that initialization processing can be performed if nec-
essary.
ON: First execution
OFF: Not executable for the first time or not being executed.
ON when an online editing process is waiting.
ON: Waiting for online editing
OFF: Not waiting for online editing
If another online editing command is received while waiting, the
other command will not be recorded and an error will occur.
ON when an online editing process is being executed.
ON: Online editing in progress
OFF: Online editing not in progress
ON when a network instruction (SEND, RECV, CMND, PMCR,
TXDU, or RXDU) or background execution can be executed with
the corresponding port number. Bits 00 to 07 correspond to com-
munications ports 0 to 7.
ON: Network instruction is not being executed
OFF: Network instruction is being executed (port busy)
When two or more network instructions are programmed with the
same port number, use the corresponding flag as an execution
condition to prevent the instructions from being executed simulta-
neously.
(The flag for a given port is turned OFF while a network instruc-
tion with that port number is being executed.)
Cleared when an instruction is executed.
ON when CJ2 instructions can be used. This flag is ON by default.
This flag can be used only with the following instructions: SEND2,
CMND2, PMCR2, and RECV2.
ON when there is a communications port available for automatic
allocation when executing communications instructions (SEND,
RECV, CMND, PMCR, TXDU, or RXDU).
ON: Communications port available
OFF: Communications port not available
Use this flag to confirm whether a communications port is avail-
able for automatic allocation before executing communications
instructions when using 9 or more communications instructions
simultaneously.
Appendices
Status
Write timing/
Status at
after mode
Related flags, set-
startup
change
tings
---
---
---
Cleared
---
---
Cleared
Cleared
---
Cleared
---
---
Cleared
Cleared
A527
Cleared
Cleared
A527
Cleared
---
---
---
Updated
---
accord-
ing to
internal
status
(cleared).
Cleared
---
---
A-113

Advertisement

Table of Contents
loading

Table of Contents