Omron CJ2 CPU UNIT SOFTWARE User Manual page 602

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

Appendices
Address
Name
Words
Bits
A275
A275.00
High-speed
Counter 1 Range
Comparison
Condition 1 In-
range Flag
A275.01
High-speed
Counter 1 Range
Comparison
Condition 2 In-
range Flag
A275.02
High-speed
Counter 1 Range
Comparison
Condition 3 In-
range Flag
A275.03
High-speed
Counter 1 Range
Comparison
Condition 4 In-
range Flag
A275.04
High-speed
Counter 1 Range
Comparison
Condition 5 In-
range Flag
A275.05
High-speed
Counter 1 Range
Comparison
Condition 6 In-
range Flag
A275.06
High-speed
Counter 1 Range
Comparison
Condition 7 In-
range Flag
A275.07
High-speed
Counter 1 Range
Comparison
Condition 8 In-
range Flag
A275.08
High-speed
Counter 1 Com-
parison In-
progress Flag
A275.09
High-speed
Counter 1 Over-
flow/Underflow
Flag
A275.10
High-speed
Counter 1 Count
Direction
A-118
Function
These flags indicate whether the PV is within any of the eight
ranges when high-speed counter 1 is being operated in range-
comparison mode with upper and lower limits. The In-range
Flags, however, will be ON whenever the comparison value is
within the range regardless of the whether the high-speed counter
is set to execute the interrupt task when the range is entered or
left.
OFF: Not in range, ON: In range
This flag indicates whether a comparison operation is being exe-
cuted for high-speed counter 1.
OFF: Stopped, ON: Comparing
This flag indicates when an overflow or underflow has occurred in
the PV of high-speed counter 1. (Used with the linear mode
counting range only.)
OFF: Normal, ON: Error
This flag indicates whether high-speed counter 1 is currently
being incremented or decremented. The counter PV for the cur-
rent cycle is compared with the PV in last cycle to determine the
direction.
OFF: Decrementing, ON: Incrementing
Status
Write timing/
Status at
after mode
Related flags, set-
startup
change
tings
Cleared
Cleared
• Refreshed each
cycle during over-
seeing process.
• Refreshed when
PRV(881) instruc-
tion is executed to
read the results of
range compari-
son.
• Refreshed when
INI(880) instruc-
tion is executed to
change PV or ring
counter maxi-
mum value.
• Refreshed when
reset.
Cleared
Cleared
Refreshed when
comparison opera-
tion starts or stops.
Cleared
Cleared
• Cleared when the
PV is changed.
• Refreshed when
an overflow or
underflow occurs.
---
---
• Setting used for
high-speed
counter, valid dur-
ing counter oper-
ation.
• Refreshed each
cycle during over-
seeing process.
• Refreshed when
PRV(881) instruc-
tion is executed to
read the PV or
status.
CJ2 CPU Unit Software User's Manual