Omron CJ2 CPU UNIT SOFTWARE User Manual page 641

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

Address
Name
Words
Bits
A620
A620.01
Communica-
tions Unit 0,
Port 1 Set-
tings Chang-
ing Flag
A620.02
Communica-
tions Unit 0,
Port 2 Set-
tings Chang-
ing Flag
A620.03
Communica-
tions Unit 0,
Port 3 Set-
tings Chang-
ing Flag
A620.04
Communica-
tions Unit 0,
Port 4 Set-
tings Chang-
ing Flag
A621 to
A621.00
Communica-
A635
to
tions Units 1
A635.04
to 15, Ports 1
to 4 Settings
Changing
Flag
A650
A650.00
Program
to
Replace-
A650.07
ment Com-
pleted Flag
A650.14
Replace-
ment Error
Flag
A650.15
Replace-
ment Start
Bit
CJ2 CPU Unit Software User's Manual
Function
The corresponding flag will be ON when the settings for
that port are being changed.
The flag will be turned ON when STUP(237) is executed
and it will be turned OFF by an event issued from the
Serial Communications Unit after the settings have
been changed.
It is also possible for the user to indicate a change in
serial port settings by turning these flags ON.
• Normal completion (i.e., when A650.14 is OFF)
01 hex: The program file (.OBJ) was replaced.
• Error (i.e., when A650.14 is ON)
00 hex: A fatal error occurred.
01 hex: A memory error occurred.
11 hex: Memory is write-protected.
12 hex: The program replacement password is
wrong.
21 hex: There is no Memory Card.
22 hex: The specified file does not exist.
23 hex: The size of the specified file exceeds the
capacity for the model (memory error).
31 hex: One of the following operations is being
executed.
• An operation related to file memory is
being executed.
• A user program is being written.
• The operating mode is being changed.
ON when the Replacement Start Bit (A650.15) is turned
ON to replace the program, but there is an error. If the
Replacement Start Bit is turned ON again, the Replace-
ment Error Flag will be turned OFF.
Program replacement starts when the Replacement
Start Bit is turned ON if the Program Password (A651) is
valid (A5A5 hex). Do not turn OFF the Replacement
Start Bit during program replacement.
When the power is turned ON or program replacement
is completed, the Replacement Start Bit will be turned
OFF, regardless of whether replacement was completed
normally or in error.
It is possible to confirm if program replacement is being
executed by reading the Replacement Start Bit using
the CX-Programmer, PT, or host computer.
Status
after
Status at
Settings
mode
startup
change
ON: Changing
Retained
Cleared
OFF: Not changing
---
Retained
Cleared
ON: Replacement
Retained
Cleared
error
OFF: No replace-
ment error, or the
Replacement Start
Bit (A65015) is ON.
ON: Program
Retained
Cleared
replaced
OFF: Replace-
ment completed, or
after power is
turned ON
Appendices
Write timing/
Related flags,
settings
---
---
---
---
---
---
---
---