Omron CJ2 CPU UNIT SOFTWARE User Manual page 617

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

Address
Name
Words
Bits
A360
A360.01
Executed FAL
to
to
Number Flags
A391
A391.15
A392
A392.04
Serial Port Error
Flag
A392.05
Serial Port Send
Ready Flag (No-
protocol mode)
A392.06
Serial Port
Reception Com-
pleted Flag
(No-protocol
mode)
A392.07
Serial Port
Reception Over-
flow Flag
(No-protocol
mode)
A393
A393.00
Serial Port PT
to
Communications
A393.07
Flag
A393.08
Serial Port PT
to
Priority Regis-
A393.15
tered Flags
A393.00
Serial Port
to
Reception
A393.15
Counter (No-pro-
tocol mode)
CJ2 CPU Unit Software User's Manual
Function
The flag corresponding to the specified FAL number will be turned
ON when FAL(006) is executed. Bits A360.01 to A391.15 corre-
spond to FAL numbers 001 to 511.
ON: That FAL was executed
OFF: That FAL wasn't executed
The flag will be turned OFF when the error is cleared.
ON when an error has occurred at the RS-232C port. (Do not
access this bit in Peripheral Bus Mode, 1:N NT Link mode, or
Serial PLC Link Polling/Polled Unit mode.)
ON: Error
OFF: No error
ON when the RS-232C port is able to send data in no-protocol
mode.
ON: Able-to-send
OFF: Unable-to-send
ON when the RS-232C port has completed the reception in no-
protocol mode.
• When the number of bytes was specified: ON when the speci-
fied number of bytes is received.
• When the end code was specified: ON when the end code is
received or 256 bytes are received.
ON when a data overflow occurred during reception through the
RS-232C port in no-protocol mode.
• When the number of bytes was specified: ON when more data
is received after the reception was completed but before
RXD(235) was executed.
• When the end code was specified: ON when more data is
received after the end code was received but before RXD(235)
was executed.
ON when 257 bytes are received before the end code.
ON: Overflow
OFF: No overflow
The corresponding bit will be ON when the serial port is communi-
cating in NT Link Mode or in Serial PLC Link Mode.
Bits 0 to 7 correspond to units 0 to 7.
ON: Communicating
OFF: Not communicating
The corresponding bit will be ON for the PT that has priority when
the RS-232C port is communicating in NT link mode.
Bits 0 to 7 correspond to units 0 to 7.
These flags are written when the priority registration command is
received.
ON: Priority registered
OFF: Priority not registered
Indicates (in binary) the number of bytes of data received when
the RS-232C port is in no-protocol mode.
Appendices
Status
Write timing/
Status at
after mode
Related flags, set-
startup
change
tings
Retained
Cleared
Refreshed when
error occurs.
A402.15
Retained
Cleared
Refreshed when
error occurs.
Retained
Cleared
Written after trans-
mission
Retained
Cleared
Written after recep-
tion
Retained
Cleared
Retained
Cleared
Refreshed when
there is a normal
response to the
token.
Retained
Cleared
See Function col-
umn.
Retained
Cleared
Refreshed when
data is received.
A-133