Omron CJ2 CPU UNIT SOFTWARE User Manual page 284

Cj2 cpu unit software
Hide thumbs Also See for CJ2 CPU UNIT SOFTWARE:
Table of Contents

Advertisement

8 I/O Allocations and Unit Settings
Creating I/O Tables with Units Connected
Allocation Method
I/O is allocated in the same way as for automatic allocation. Refer to 8-1-2 Automatic Allocation for
information on the allocation method.
I/O Allocation Procedure
With the CX-Programmer online, use the following procedure to create I/O tables for the connected
Units.
1
Double-click IO Table in the project tree in the main window. The I/O Table Window will be dis-
played.
2
Select Options and then Create. The models and positions of the Units mounted to the Racks
will be written to the CPU Unit as the registered I/O tables.
Procedure for Comparing I/O Tables
Use the following procedure to compare the I/O tables with the physically connected Units while the
CX-Programmer is online.
1
Double-click IO Table in the project tree in the main window. The I/O Table Window will be dis-
played.
2
Select Options and then Verify. The models and positions of Units mounted to the Racks will be
compared with the registered I/O tables. Check the results when they are displayed.
Creating I/O Tables with User-specified Allocations
Allocation Method
Rather than allocating I/O automatically for the connected Units, I/O can be allocated manually
using the following methods to create the desired I/O tables.
• Allocating words to Units at any positions on the Racks
• Reserving words
• Specifying first words on Racks
• Allocating I/O without the physical Units
Words are allocated as follows:
Unit classification
Basic I/O Units
Special I/O Units
CPU Bus Units
Pulse I/O Module
8-10
There are some restrictions on settings, but the following are possible:
The word that is allocated to any Unit on any Rack can be specified. Consecu-
tive words will be allocated to following Unit in the order they are connected.
This can be done to create 63 user-set allocation groups.
Words are allocated according to front-panel rotary switch settings (i.e., unit
numbers).
The Pulse I/O Module closest to the CPU Unit is Pulse I/O Module 0 and the
other one is Pulse I/O Module 1.
Allocation method
CJ2 CPU Unit Software User's Manual