Health And Status Messages - Paradyne HotWire 7974 User Manual

Standalone termination unit
Table of Contents

Advertisement

Health and Status Messages

7970-A2-GB20-00
The following messages can appear in the first column of the System and Test
Status screen. The highest priority Health and Status message also appears on
all ATI screens on the bottom right.
Table 5-1. Health and Status Messages (1 of 2)
Message
What Message Indicates
System Operational
There are no problems
detected.
LOS at Net, Pt 1
An LOS (Loss Of Signal)
condition has been
detected on the network
interface.
Mismatch Rate
The LTU, set to Fixed Rate
mode, is attempting to
operate at a DSL line
speed faster than the NTU
can handle.
NTU/LTU Mismatch
The NTU is not configured
the same as the LTU.
OOF at Net
An OOF (Out Of Frame)
condition has been
detected at the network
interface.
LOS at DSX-1
An LOS (Loss Of Signal)
LOS at G.703
condition has been
detected on the DSX-1 or
G.703 interface.
LOF at DSX-1
An LOF (Loss Of Frame)
LOF at G.703
condition has been
detected on the DSX-1 or
G.703 interface.
AIS at DSX-1
An Alarm Indication Signal
AIS at G.703
(AIS) is being received by
the DSX-1 or G.703
interface.
EER at Net
An EER (Excessive Error
Rate) condition has been
detected on the network
interface at Port 1. The
condition is cleared when
the error rate falls below
the threshold value
currently configured.
EER at DSX-1
An EER (Excessive Error
EER at G.703
Rate) condition has been
detected on the DSX-1 or
G.703 interface.
August 1999
Monitoring the Unit
What To Do
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
Set the LTU to a DSL line speed
available to the NTU.
Configure units to match.
Contact network provider.
1. Verify proper framing.
2. Contact network provider.
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
1. Verify that the units line framing
and line coding are compatible.
2. Contact network provider.
1. Ignore condition if 511 test active.
2. Contact network provider.
1. Verify the attached equipment
coding is compatible.
2. Contact network provider.
5-3

Advertisement

Table of Contents
loading