Hotwire 79xx Standalone Termination Unit LEDs
5-16
The following table contains a description of the LEDs on the Hotwire 79xx
Standalone Termination Unit front panel.
Label
Color
LED is . . .* Indicating . . .
POWER
Green
On
Off
Slow Cycling
Pulsing
ALARM
Red
On
Off
TEST
Yellow
On
Off
Slow Cycling
DSL
Green
On
Off
Slow Cycling
Fast Cycling
DSX-1
Green
On
DTE
Off
G.703
Slow Cycling
Fast Cycling
*
Slow Cycling:
LED turns off and on in equal duration once per second.
Fast Cycling:
LED turns off and on in equal duration 5 times per second.
Pulsing:
LED turns off momentarily once per second.
August 1999
Unit failure.
No power to the unit.
Unit is in minimum mode and a download is
required.
Normal Operation.
Device failure, or self-test has failed.
Self-test passed.
Loopback test or 511 test pattern in progress.
No tests in progress.
Self-test in progress.
DSL link is up.
The DSL link is down.
DSL training in progress.
An OOF condition.
DTE port is operational.
No signal on DTE port.
DSX-1:
Yellow Alarm Indication received.
Sync DTE: Not applicable.
G.703:
Remote Alarm Indication received.
DSX-1:
OOF, LOF, EER, or AIS condition.
Sync DTE: Not applicable.
G.703:
OOF, LOF, EER, or AIS condition.