Health and Status Messages

7900-A2-GB21-00
The following messages can appear in the first column of the System and Test
Status screen. The highest priority Health and Status message also appears on
all ATI screens on the bottom right.
Table 7-1. Health and Status Messages (1 of 2)
Message
What Message Indicates
AIS at DSX-1
An Alarm Indication Signal
AIS at G.703
(AIS) is being received by
the DSX-1 or G.703
interface.
DeviceFailed
An internal error has been
yyyyyyyy
detected by the operating
software. yyyyyyyy
indicates the 8-digit
hexadecimal failure code.
Download Failed
A firmware download was
interrupted.
EER at DSX-1
An EER (Excessive Error
EER at G.703
Rate) condition has been
detected on the DSX-1 or
G.703 interface.
EER at Net
An EER (Excessive Error
Rate) condition has been
detected on the network
interface at Port 1. The
condition is cleared when
the error rate falls below
the threshold value
currently configured.
Fallback Rate
The LTU had a loss of
signal, and when the line
was restored it did not
resynchronize to the last
known rate, but to a lower
rate.
LOF at DSX-1
An LOF (Loss Of Frame)
LOF at G.703
condition has been
detected on the DSX-1 or
G.703 interface.
LOS at DSX-1
An LOS (Loss Of Signal)
LOS at G.703
condition has been
detected on the DSX-1 or
G.703 interface.
LOS at Net, Pt 1
An LOS (Loss Of Signal)
condition has been
detected on the network
interface.
August 2000
Monitoring and Troubleshooting
What To Do
1. Verify that the unit's line framing
and line coding are compatible.
2. Contact network provider.
1. Provide the 8-digit failure code
shown ( yyyyyyyy ) to your service
representative.
2. Reset the unit to clear the
condition and message.
Repeat the download.
1. Verify the attached equipment
coding is compatible.
2. Verify your clock configuration.
3. Contact network provider.
1. Ignore condition if 511 test active.
2. Contact network provider.
1. Verify that the network cable is
securely attached at both ends.
2. From the Control screen, select
Reset AutoRate to see if the unit
will retrain at a higher rate.
3. Contact network provider.
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
1. Verify proper framing.
2. Contact network provider.
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
7-3