The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-bindings are different for each particular interface. Diagnostic tests are
only supported on the physical T1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:
7970-A2-GB20-00
enterpriseTestStart/Stop
Interface
Variable-Bindings
H
DSL Network
ifIndex (RFC 1573)
H
ifAdminStatus (RFC 1573)
H
ifOperStatus (RFC 1573)
H
ifType (RFC 1573)
H
ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopLLB – Initiates a Local
Loopback.
– testLoopPLB – Initiates a
Payload Loopback.
– testLoopRLB – Initiates a
Remote Loopback.
– testSendMon511 – Initiates a
Send and Monitor 511 test.
– testSendLLBUp – Initiates an
LLB Up message to the remote
unit.
– testSendLLBDown – Initiates an
LLB Down message to the
remote unit.
H
DSX-1 or
ifIndex (RFC 1573)
G.703
H
ifAdminStatus (RFC 1573)
H
ifOperStatus (RFC 1573)
H
ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopExternalDTE
August 1999
Standards Compliance for SNMP Traps
Possible Cause
H
enterpriseTest Start – Any
one of the following tests is
active on the interface:
– Line Loopback
– Payload Loopback
– Repeater Loopback
– Remote Line Loopback
– Send and Monitor 511
H
enterpriseTest Stop – No tests
currently running on the
interface.
B-5