Configuring the Unit Using the Internal Switches

Switchpack Definitions for Models 7975 and 7985

4-6
Table 4-4 lists Switchpack S1 definitions.
Table 4-4. Switchpack S1 Definitions (Models 7975 and 7985)
Switch # . . .
Allows you to . . .
1
Enable or disable Switchpacks S1 and S2.
OFF = Switchpacks Disabled
ON = Switchpacks Enabled
2
Control Sync Port Type.
OFF = EIA-530, RS-449, or X.21
ON = V.35
3
Select the unit's timing source. Only valid for LTU configured units.
OFF = Internal clock
ON = External Clock
4, 5, 6, 7, 8
Control Sync Port Data Rate (refer to Table 4-5,
Rates)
NOTE:
All OFF = 2048 kbps (1024 kbps for 1 Mbps units)
Use Table 4-5 to set the Sync Port Payload Rate. Defaults are shown in bold.
NOTE:
Sync Port and DSL Line Rates can only be selected from units configured as
LTU (Switchpack S2 #1) with AutoRate disabled (Switchpack S2 #2).
August 1999
Switches 4 through 8 are only used when the unit is
configured as an LTU and AutoRate is disabled.
Default in Bold
Selectable Payload
7970-A2-GB20-00