Table A-1. Network Interface Options (2 of 2)
DSL Line Rate
Possible Settings (Models 7974, 7984): 400, 528, 784, 1040, 1552
Default Setting (Models 7974, 7984): 1552
Possible Settings (Models 7975, 7985): 144, 272, 400, 528, 784, 1040,
1552 (2 Mbps unit only), 2064 (2 Mbps unit only)
Default Setting (Models 7975, 7985): 144
Possible Settings (Models 7976, 7986): 400, 528, 784, 1040, 1552, 2064
Default Setting (Models 7976, 7986: 2064
Determines the fixed line rate of the LTU when AutoRate is disabled, and the maximum
rate to which the unit can be set when Autorate is enabled.
H
DSL Line Rate is only available when the unit is configured as an LTU.
144 to 2064 – The fixed DSL Line Rate, in kbps.
Payload Rate
Possible Settings: 64, 128, 192, 256, 320, 384, 448, 512, 576, 640, 704, 768, 832, 896,
960, 1024, 1088, 1152, 1216, 1280, 1344, 1408, 1472, 1536, 1600, 1664, 1728, 1792,
1856, 1920, 1984, 2048
Default Setting: [Highest multiple of 64 kbps supported by the DSL Line Rate]
Models 7974, 7976, 7984, 7986. When the NTU has an EIA-530-A interface, the
Payload Rate set on the LTU determines the port speed of the synchronous port of the
NTU.
H
Payload Rate is only available when the unit is configured as an LTU. Rates above
1536 available only on Models 7976 and 7986.
64 to 2048 – The Payload Rate, in kbps.
Peer IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear
Default Setting: 000.000.000.000
Specifies the peer IP address for the NTU, to provide remote management providing the
remote management link on the DSL loop.
H
Peer IP Address is only available when the unit is configured as an LTU, and is not
running in IP Conservative mode.
Address Field – (001.000.000.000 – 223.255.255.255) – Enter an address for the peer
unit. The range for the first byte is 001 to 223, with the exception of 127. The range for
the remaining three bytes is 000 to 255.
Clear – Clears the IP address field and sets to all zeros.
Circuit Identifier
Possible Settings: [ASCII Text], Clear
Default Setting: [blank]
Uniquely identifies the circuit number of the transmission vendor's DSL line for
troubleshooting purposes.
[ASCII Text] – Enter a maximum of 128 characters. All printable ASCII characters
except ^ (caret) are allowed.
Clear – Clears the field.