H Network Interface Options Menu - Paradyne HotWire 7974 User Manual

Standalone termination unit
Table of Contents

Advertisement

Configuration Option Tables
Network Interface Options Menu
Î
A-2
For Network Interface Options, refer to Table A-1. To access the Network
Interface Options screen, follow this menu selection sequence:
Main Menu
Configuration
main/config/network
Margin Threshold:
Excessive Error Rate Threshold:
AutoRate:
DSL Line Rate:
Payload Rate:
Peer IP Address:
Circuit Identifier:
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu
Save
Table A-1. Network Interface Options (1 of 2)
Margin Threshold
Possible Settings: –5db, –4db, –3db, –2db, –1db, 0db, 1db, 2db, 3db, 4db, 5db, 6db,
7db, 8db, 9db, 10db
Default Setting: 0db
Determines the level, expressed in decibels, at which a signal-to-noise margin alarm
condition is reported.
–5db to 10db – Sets the margin threshold to this value.
Excessive Error Rate Threshold
Possible Settings: 1E–4, 1E–5, 1E–6, 1E–7, 1E–8, 1E–9
Default Setting: 1E–6
Determines the error rate at which an excessive error rate (EER) condition is
recognized. The rate is the ratio of the number of CRC errors to the number of bits
received in a certain period.
AutoRate
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the unit automatically adjusts to the best line rate for conditions, or
is fixed at the rate in the DSL Line Rate field.
H
AutoRate is only available when the unit is configured as an LTU.
Enable – The LTU adjusts to the best line rate. The maximum rate is the setting of DSL
Line Rate.
Disable – The LTU's line rate is the DSL Line Rate selected.
August 1999
Current Configuration
NETWORK INTERFACE OPTIONS
Network
Hotwire
Model: 79xx
–3db
1E–6
Disable
1552 Kbps
1536 Kbps
111.255.255.000
Clear
Î Î
Clear
MainMenu
Exit
7970-A2-GB20-00

Advertisement

Table of Contents
loading