EIA-530-A Port
The EIA-530-A Port interface connector information is shown in Table C-5.
7970-A2-GB20-00
Table C-5. EIA-530-A Port Interface Connector
Signal
Shield
Signal Common
Signal Common
Transmitted Data
Received Data
Request to Send
Clear to Send
Received Line Signal Detector
DCE Ready
DTE Ready
Transmit Signal Element
Timing (DTE Source)
Transmit Signal Element
Timing (DCE Source)
Receiver Signal Element
Timing (DCE Source)
Local Loopback
Remote Loopback
Test Mode
August 1999
Cables and Pin Assignments
Circuit
ITU-T
Mnemonic
Number
AB
102A
AC
102B
BA
103
BB
104
CA
105
CB
106
CF
109
CC
107
CD
108/1, /2
DA
113
DB
114
DD
115
LL
141
RL
140
TM
142
Direction
Pin
1
7
23
To DSU/CSU
2 (A)
14 (B)
From DSU/CSU
3 (A)
16 (B)
To DSU/CSU
4 (A)
19 (B)
From DSU/CSU
5 (A)
13 (B)
From DSU/CSU
8 (A)
10 (B)
From DSU/CSU
6
To DSU/CSU
20
To DSU/CSU
11 (B)
24 (A)
From DSU/CSU
12 (B)
15 (A)
From DSU/CSU
17 (A)
9 (B)
To DSU/CSU
18
To DSU/CSU
21
From DSU/CSU
25
C-7