Paradyne HotWire 7974 User Manual page 62

Standalone termination unit
Table of Contents

Advertisement

Monitoring the Unit
5-8
Network Error Statistics are collected for:
H
ES (Errored Seconds): Seconds during which one or more CRC error
events occurred.
H
SES (Severely Errored Seconds): Seconds during which more than
320 cyclic redundancy check (CRC) error events or at least one Out of Frame
(OOF) event occurred.
H
FEBE (Far-End Block Errors): Errors reported by the remote equipment.
H
Complete: Whether the interval register contains data for a complete
900-second interval.
Use the virtual function keys to page through the intervals and clear statistics.
This Field . . .
Contains . . .
Current Interval
The number of seconds which have elapsed in the current
Timer
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter resets every 15 minutes.
Error Events
A running total of CRC errors. Range 0–65535. This counter
Counter
resets when the near-end data is cleared.
Current Int
Performance data for the current 15-minute interval.
Interval xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of xx is from 01 to 96.
Worst Interval
The number of the interval with the worst (highest) performance
data for both the near- and far-end statistics. If two or more
intervals are equal, the oldest interval is displayed.
Near and Far Tot
A 24-hour running total of the near- and far-end performance
statistics.
August 1999
7970-A2-GB20-00

Advertisement

Table of Contents
loading

Table of Contents