Health and Status

7984-A2-GB20-10
The following messages can appear in the first column of the System and Test
Status screen. The highest priority Health and Status message also appears on
all ATI screens on the bottom right.
Table 4-1. Health and Status Messages (1 of 2)
Message
What Message Indicates
System Operational
There are no problems
detected.
LOS at Net, Pt 1
An LOS (Loss Of Signal)
condition has been
detected on the network
interface. No signal is
being received on Port 1,
possibly due to a local
network problem.
OOF at Net, Pt 1
An OOF (Out Of Frame)
condition has been
detected at the network
interface.
LOS at DSX-1, Pt 1
An LOS (Loss Of Signal)
condition has been
detected on the DSX-1
interface.
NTU/LTU Mis match,
The NTU is not configured
Pt 1
the same as the LTU.
LOF at DSX-1, Pt 1
An LOF (Loss Of Frame)
condition has been
detected on the DSX-1
interface.
AIS at DSX-1, Pt 1
An Alarm Indication Signal
(AIS) is being received by
the DSX-1 interface.
EER at Net, Pt 1
An EER (Excessive Error
Rate) condition has been
detected on the network
interface at Port 1. The
condition is cleared when
the error rate falls below
the threshold value
currently configured.
EER at DSX-1, Pt 1
An EER (Excessive Error
Rate) condition has been
detected on the DSX-1
interface.
Yellow alarm at
A Yellow Alarm Indication
DSX-1, Pt 1
signal is being received by
the DSX-1 interface.
February 1999
Monitoring the Unit
What To Do
1. Verify that the network cable is
securely attached at both ends.
2. Verify proper NTU and LTU
configuration
3. Contact network provider.
Contact network provider.
1. Verify proper framing.
2. Contact network provider.
Configure units to match.
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
1. Verify that the units line framing
and line coding are compatible.
2. Contact network provider.
1. Ignore condition if 511 test active.
2. Contact network provider.
1. Verify the attached equipment
coding is compatible.
2. Contact network provider.
1. Verify that the units line framing
and line coding are compatible.
2. Contact network provider.
4-3