Paradyne HotWire 7974 User Manual page 134

Standalone termination unit
Table of Contents

Advertisement

Configuration Option Tables
A-28
Table A-11. SNMP Traps Options (2 of 2)
Enterprise Specific Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if SNMP traps are generated for enterprise-specific events.
Enable – SNMP traps are generated for enterpriseSpecific events.
NOTE:
Refer to
Enterprise Specific Traps
for SNMP Traps .
Disable – No enterprise-specific event traps are sent.
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.
Disable – No linkUp or linkDown SNMP traps are generated.
Up – A linkUp trap is generated when the unit recognizes that one of the communication
interfaces is operational.
Down – A linkDown trap is generated when the unit recognizes a failure in one of the
communication interfaces.
Both – Sends trap messages for detection of both linkUp and linkDown .
NOTE:
Refer to
linkUp and linkDown
SNMP Traps .
Link Traps Interfaces
Possible Settings: Network, [DSX, SYNC, or G.703], All
Default Setting: All
Determines if the SNMP linkUp , SNMP linkDown , and interface-related
enterpriseSpecific traps are generated for the network interface, DTE port, or both.
Depending on the model, the DTE option appears as DSX, SYNC, or G.703.
Network – SNMP trap messages are generated for the network interface.
DSX, SYNC, or G.703 – SNMP trap messages are generated for the DTE port.
All – SNMP trap messages are generated for the network interface and the DTE ports.
August 1999
in Appendix B, Standards Compliance
in Appendix B, Standards Compliance for