4.
In [Detailed settings] for custom paper, select 1232: [Fusing Temperature] and decrease
the temperature setting for the fusing heat roller by 5°C according to the color mode you
wish to use.
• 1232-01: Fusing Temperature: BW/FC/FCS: Heat Roller Temp
• 1232-06: Fusing Temperature: FCS: Heat Roller Temp: Clear/Special
• 1232-07: Fusing Temperature: FCS: Heat Roller Temp: White
• 1232-08: Fusing Temperature: FCS: Heat Roller Temp: Metallic
• 1232-26: Fusing Temperature: S: Heat Roller Temp: Clear/Special
• 1232-27: Fusing Temperature: S: Heat Roller Temp: White
• 1232-28: Fusing Temperature: S: Heat Roller Temp: Metallic
• 1232-46: Fusing Temperature: BW/FC/FCS: Fuser Setting HQ: Heat Roller Temp
• 1232-51: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: Clear/Special
• 1232-52: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: White
• 1232-53: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: Metallic
• 1232-71: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: Clear/Special
• 1232-72: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: White
• 1232-73: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: Metallic
Print the image. Has the problem been resolved? (10 or more sheets of A4 paper)
Yes
Finished!
No
Set [Print Speed] to [Low] according to Step 3, and then go to the next step.
5.
Decrease the temperature setting for the fusing heat roller by 20°C according to the color
mode you wish to use.
• 1232-01: Fusing Temperature: BW/FC/FCS: Heat Roller Temp
• 1232-06: Fusing Temperature: FCS: Heat Roller Temp: Clear/Special
• 1232-07: Fusing Temperature: FCS: Heat Roller Temp: White
• 1232-08: Fusing Temperature: FCS: Heat Roller Temp: Metallic
• 1232-26: Fusing Temperature: S: Heat Roller Temp: Clear/Special
• 1232-27: Fusing Temperature: S: Heat Roller Temp: White
• 1232-28: Fusing Temperature: S: Heat Roller Temp: Metallic
• 1232-46: Fusing Temperature: BW/FC/FCS: Fuser Setting HQ: Heat Roller Temp
• 1232-51: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: Clear/Special
• 1232-52: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: White
• 1232-53: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: Metallic