• 1231-17: Print Speed: S: Fuser Setting HQ: Metallic
3.
Select 1232: [Fusing Temperature] and decrease the fusing heat roller's temperature by
20°C.
• 1232-01: Fusing Temperature: BW/FC/FCS: Heat Roller Temp
• 1232-06: Fusing Temperature: FCS: Heat Roller Temp: Clear/Special
• 1232-07: Fusing Temperature: FCS: Heat Roller Temp: White
• 1232-08: Fusing Temperature: FCS: Heat Roller Temp: Metallic
• 1232-26: Fusing Temperature: S: Heat Roller Temp: Clear/Special
• 1232-27: Fusing Temperature: S: Heat Roller Temp: White
• 1232-28: Fusing Temperature: S: Heat Roller Temp: Metallic
• 1232-46: Fusing Temperature: BW/FC/FCS: Fuser Setting HQ: Heat Roller Temp
• 1232-51: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: Clear/Special
• 1232-52: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: White
• 1232-53: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: Metallic
• 1232-71: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: Clear/Special
• 1232-72: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: White
• 1232-73: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: Metallic
4.
In [Detailed settings] for custom paper, select 1232 [Correct Temp: Initial Feed] and set
the temperature adjustment at the time of initial paper feeding to "0".
• 1232-02: Fusing Temperature: BW/FC/FCS: Correct Temp: Initial Feed
• 1232-10: Fusing Temperature: FCS: Correct Temp: Initial Feed: Clear/Special
• 1232-11: Fusing Temperature: FCS: Correct Temp: Initial Feed: White
• 1232-12: Fusing Temperature: FCS: Correct Temp: Initial Feed: Metallic
• 1232-30: Fusing Temperature: S: Correct Temp: Initial Feed: Clear/Special
• 1232-31: Fusing Temperature: S: Correct Temp: Initial Feed: White
• 1232-32: Fusing Temperature: S: Correct Temp: Initial Feed: Metallic
• 1232-47: Fusing Temperature: BW/FC/FCS: Fuser Setting HQ: Correct Temp: Initial Feed
• 1232-55: Fusing Temperature: FCS: Fuser Setting HQ: Correct Temp: Initial Feed: Clear/
Special
• 1232-56: Fusing Temperature: FCS: Fuser Setting HQ: Correct Temp: Initial Feed: White
• 1232-57: Fusing Temperature: FCS: Fuser Setting HQ: Correct Temp: Initial Feed: Metallic
• 1232-75: Fusing Temperature: S: Fuser Setting HQ: Correct Temp: Initial Feed: Clear/Special
• 1232-76: Fusing Temperature: S: Fuser Setting HQ: Correct Temp: Initial Feed: White
• 1232-77: Fusing Temperature: S: Fuser Setting HQ: Correct Temp: Initial Feed: Metallic