(13) [CM] Setting of the machine head motor stop time

(14) [CN] Setting of the position compensation of the machine head and the supply device

(15) [CO] Setting of the model

Stop time of the machine head when operating [CJ] is set. This setting performs op-
eration and stop based on the number of revolutions set in [CK] and operating time
of set value in [CL].
This is not displayed unless M-2 of [CJ] setting is set.
The machine head operates within the setting time regardless of the
number of stitches.
Compensation of the position of the machine head and the supply device is per-
formed.
Positioning using the positioning jig or the like is performed in the production line.
However, the final fine adjustment is electrically performed.
0 : MOL-254
1 : MOL-254N
Carry out setting in accordance with the model of the sewing machine you use.
If this setting does not match the model, the belt loop length will not be correct.