(3) Changing the fork
Center-to-center
alignment
Center-
to-center
alignment
(4) Changing the presser foot
❸ ❸
❺ ❺
❶ ❶
❷ ❷
❶ ❶
❷ ❷
❹ ❹
– 33 –
1) Loosen cover setscrews ❶ to remove the cover.
2) Loosen setscrews ❷ . Move the near-side fork
(indication mark ❸ ) to align it with scale ❹ (loop
length). Then, tighten setscrews ❷ .
* At this time, the fork and the needle are at the
position where their centers are aligned.
❹ ❹
❸ ❸
1) Loosen two setscrews ❶ of the front presser foot
base.
2) Move the fork to the underside of the needle.
Move front presser foot base ❷ in the direction
of the arrow.
3) Lower presser foot ❸ to the position at which the
claw of loop guide ❹ fits in notch portion ❺ of
the fork, and tighten two setscrews ❶ of the front
presser foot base.
* The positional relation between the presser foot
(the loop guide and the garment body presser)
and the loop is as shown in the figure.