Space between needles A
C

(9) Setting of the belt loop splice detection

(10) Setting of the belt loop detection

For the aforementioned (9) and (10)
When the pattern is changed, set again since data is memorized by each pattern data.
Therefore, it is not necessary to set again if the sewing products are the same since pattern data and loop
that have been entered once are controlled by the machine.
Refer to
"VII-4. Adjusting the belt loop splice detector" P.40
When setting the belt loop splice and detection using the actual product, it is possible to set with either (9) or
(10).
B
Loosening amount
Make the machine memorize the thickness of belt loop splice.
Make the machine memorize the thickness of belt loop and make the machine stop
when the belt loop runs out.
1) Max. loosening amount
Loosening amount is the amount C which has
cut B.
Operate the machine referring to the following
table.
Space between
needles A
43 to 45 mm
46 to 50 mm
51 to 55 mm
56 to 60 mm
61 to 65 mm
66 to 70 mm
for the setting procedure.
– 24 –
Loosening
amount C
7 mm
8 mm
9 mm
10 mm
11 mm
12 mm