Explanation Of The Counter - JUKI MOL-254N Instruction Manual

Table of Contents

Advertisement

2. Explanation of the counter

Count operation means that number of times of sewing is added or subtracted when sewing is completed
while one loop is regarded as "1".
When the number of times of sewing reaches the specified value, the sewing machine automatically stops,
and the hook on front side widens to front side. Turn OFF the power and replace the bobbin with a new one.
Operation
◦ Make the set ready LED go out.
(Press the set ready key (green color), and light-up and go-off are repeated.)
◦ Press the counter key
When the screen change-over key
er is changed over UP counter to DOWN counter.
◦ Count can be individually set to the first hook and the second hook.
・ This setting is convenient when bobbin thread amount to be used of the respective hooks is different
from each other.
・ When replacing bobbins as a set, count UP or DOWN operates by setting of either one only.
<AA>
1st hook counter
<AB>
1st hook counter value (set value)
When counter value is set to "0", count-end operation is not performed.
<AC> 2nd hook counter
<AD> 2nd hook counter value (set value)
When counter value is set to "0", count-end operation is not performed.
<AE>
Total counter
(UP counter function only)
◦ Clear with the reset key.
(Even when the power is turned OFF, data will remain. Be sure to reset before starting
counting.)
and the count setting screen is displayed as given below.
is pressed while selecting pictograph Nos. <AA> to <AD>, the count-
– 19 –
Display of UP counter
Press the reset key to clear "0".
Display at the time of DOWN counter
Set value is entered with the ten keys.

Advertisement