4. Adjusting the belt loop splice detector

WARNING
To secure safety, be sure to conduct adjustment while the Set ready LED goes out.
This adjustment has to be carried out with the power switch ON.
* Belt Loop *
P=1
Key [1] = level
Adjustment
Key [R] = Return
* Belt Loop *
[7] = Feed
[9] = set
[R] = Return
Adjusting the belt loop splice detector
Numeric value input method (applied volume)
When the pattern No. is changed, it is necessary to re-input splice level. However, when chang-
ing other setting using the same belt loop,the value can be directly entered by entering the value
with the ten keys in flashing state of [1I] (Thickness of splice section) and [1J] (thickness of normal
loop).
As for the numeric value, enter the same data as the pattern data that is adjusted to the actual belt
loop since there is no correlation between the numeric value and the thickness of the belt loop.
① Flashing [1I] or [1J] in the setting screen, press
the splice input screen.
level (0)
② Press the ten key [1].
level (30)
The display screen is as shown on the left side. When pressing
the ten key [0] without inserting the belt loop in this screen, the
zero level is set.
– 40 –
1) Flashing to [1I] or [1J] in the setting screen,
press
key to enter the splice input screen.
2) Press the ten key [1].
3) When the zero level is entered, the ten key [0]
is not displayed. However, when the zero level
(when there is no loop) has not been entered
even one time, press the ten key [0].
* Refer to the Caution.
4) Set a belt loop on the machine and keep press-
ing the ten key [7] of the loop feed button to pass
the normal loop section and splice section up to
detection lever ❶ .
5) Enter the ten key [9].
6) Press the
key to return to the setting screen.
When the belt loop splice detector (potenti-
ometer ❷ and gear ❸ ) is adjusted, or CPU
circuit board is replaced, a slip occurs in
the zero level. Be sure to set the zero level
again in accordance with the procedure
given below before adjusting the belt loop
splice detector. (Refer to
input method (applied volume)"
"Numeric value
P.40.)