Example I/O Signal Connections; Input Signal - Mitsubishi Electric MELSERVO MR-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO MR-J5 Series:
Table of Contents

Advertisement

9.6

Example I/O signal connections

This is only a connection example for CN8. Refer to the following for other connection examples.
Page 53 Example I/O signal connections

Input signal

There is a delay of up to 5 ms from input to output.
For source input interface
10 m or less
*2
24 V DC
SDICOM
*1
SDI1A
SDI1B
*1 Make double wiring (SDI1A and SDI1B) for the external input wiring.
*2 Supply 24 V DC ± 10 % to interfaces from an external source. If all the I/O points have been used, there must be a total current capacity
of 0.2 A remaining. Reducing the number of I/O points decreases the current capacity. Refer to the following for current values. Although
the diagram shows the input signal and the output signal each using a separate 24 V DC power supply for illustrative purposes, the
system can be configured to use a single 24 V DC power supply.
Page 469 Connecting I/O interfaces
For sink input interface
10 m or less
*2
24 V DC
SDICOM
*1
SDI1A
SDI1B
*1 Make double wiring (SDI1A and SDI1B) for the external input wiring.
*2 Supply 24 V DC ± 10 % to interfaces from an external source. If all the I/O points have been used, there must be a total current capacity
of 0.2 A remaining. Reducing the number of I/O points decreases the current capacity. Refer to the following for current values. Although
the diagram shows the input signal and the output signal each using a separate 24 V DC power supply for illustrative purposes, the
system can be configured to use a single 24 V DC power supply.
Page 469 Connecting I/O interfaces
CN8
3
4
5
CN8
3
4
5
9 USING FUNCTIONAL SAFETY [G] (EXCULUDING MR-J5-_G_-HS_)
9.6 Example I/O signal connections
9
467

Advertisement

Table of Contents
loading

Table of Contents