Source output

When the output transistor is turned on, the current flows from the output terminal to a load using SDO24V_ as a positive
common.
A lamp, relay, or photocoupler can be driven. Connect a diode to the path for an inductive load, or connect an inrush resistor
suppression resistor to the path for a lamp load. (Rated current 5 mA to 40 mA, maximum current 50 mA, inrush current 100
mA)
A voltage drop of 2.4 V occurs in the MR-J5-_G_-HS_.
CN3
SDO24VA
SDO1A, SDO2A
CN3
SDO24VB
SDO1B, SDO2B
*1 Incorrect polarity of the power supply causes malfunction of the safety relay.
24 V DC ± 10 %
0.8 A
*1
Safety relay
Load
24 V DC ± 10 %
Load
0.8 A
*1
If polarity of diode is
reversed, servo amplifier
will malfunction.
If polarity of diode is
reversed, servo amplifier
will malfunction.
10 USING FUNCTIONAL SAFETY [G] (MR-J5-_G_-HS_)
10.7 Connecting safety I/O interfaces
10