Dimensions
[Unit: mm]
Cable connection method
Peel a part of the cable insulator to expose the external conductor as shown in the following figure, and press that part against
the ground plate with the cable clamp.
The shield clamp attachment consists of the grounding plate and clamp fitting.
6 OPTIONS AND PERIPHERAL EQUIPMENT
406
6.21 MR-ASCHP06 shield clamp attachment
20.3
90.3
12.5
2-φ5 mounting hole
Clamp fitting
External conductor
Grounding plate
Strip the cable insulator
of the clamped area.
Cable
Cutter
Cable
40 mm