3.3

Explanation of power supply system

Explanation of signals

• For the layout of connectors and terminal blocks, refer to the following.
Page 144 DIMENSIONS
• If using the MR-J5 servo amplifier with the DC power supply input, refer to the following.
Page 51 Using servo amplifier with DC power supply input
L1/L2/L3 (Connection destination: Main circuit power supply)
Supply the following power to L1, L2, and L3. For 1-phase 200 V AC to 240 V AC power supply, connect the power supply to
L1 and L3. Leave L2 open.
Power supply
3-phase 200 V AC to 240 V
AC, 50 Hz/60 Hz
1-phase 200 V AC to 240 V
AC, 50 Hz/60 Hz
3-phase 380 V AC to 480 V
AC, 50 Hz/60 Hz
P3/P4 (Connection destination: Power factor improving DC reactor)
If not using the power factor improving DC reactor, connect P3 and P4. For the MR-J5-_G_ and MR-J5-_A_ servo amplifiers,
P3 and P4 are connected from the factory.
If using the power factor improving DC reactor, disconnect P3 and P4, and connect the power factor improving DC reactor
between P3 and P4.
P+/C/D (Connection destination: Regenerative option)
If using a servo amplifier built-in regenerative resistor, connect P+ and D. P+ and D are connected from the factory.
If using a regenerative option, disconnect P+ and D, and connect the regenerative option between P+ and C.
L11/L21 (Connection destination: Control circuit power supply)
Supply the following power to L11 and L21.
Power supply
1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
1-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
3 SIGNALS AND WIRING
76
3.3 Explanation of power supply system
Servo amplifier
MR-J5-10_ to MR-
MR-J5-350_ to MR-
J5-200_
J5-700_
L1/L2/L3
L1/L3
Servo amplifier
MR-J5-10_ to MR-J5-700_/
MR-J5W2-22_ to MR-J5W2-1010_/
MR-J5W3-222_ to MR-J5W3-444_
L11/L21
MR-J5W2-22_ to
MR-J5W2-1010_
MR-J5W2-77_/
MR-J5W3-222_ to
MR-J5W3-444_
L1/L3
MR-J5-60_4_ to MR-J5-350_4_/
MR-J5-500_4_/MR-J5-700_4_
L11/L21
MR-J5-60_4_ to
MR-J5-350_4_/
MR-J5-500_4_/MR-
J5-700_4_
L1/L2/L3

Advertisement