Scc 15-F Shield Connection Clamp; Compatible Models; Applicable Wire Diameter; Cable Connection Method - Mitsubishi Electric MELSERVO MR-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO MR-J5 Series:
Table of Contents

Advertisement

6.23

SCC 15-F Shield connection clamp

This component is a terminal block for grounding the shield of the servo motor power cable on the top of the servo amplifier.
For details of the component, contact Phoenix Contact.
To install the component, two screws of M4 × 6 to 12 are required.

Compatible models

• MR-J5-500_4_/MR-J5-700_4_

Applicable wire diameter

• 8 mm to 15 mm

Cable connection method

Peel a part of the cable insulator to expose the external conductor as shown in the following figure, and secure that part by
putting it into the shield connection clamp.
External conductor
6 OPTIONS AND PERIPHERAL EQUIPMENT
410
6.23 SCC 15-F Shield connection clamp
Cable
Shield
connection clamp
Strip the cable insulator
of the clamped area.
40 mm
Cutter
Cable

Advertisement

Table of Contents
loading

Table of Contents