6.21 Torque control

Refer to 5.11 for switch to Torque control

6.21.1 Torque reference

 :Torque reference selection
 :Torque reference mode selection
 :VI/II reference point #1 rate
 :VI/II reference point #2 rate
 :RR reference point #1 rate
 :RR reference point #2 rate
 :RX reference point #1 rate
 :RX reference point #2 rate
 :BIN reference point #1 rate
 :BIN reference point #2 rate
 :Panel torque reference (Refer to 6.29.11 for details.)
・Function
Selecting a mode of torque command in torque control mode.
1)
Current signal
[Default setting]
Motor torque [%]
 = 100
 = 0
 = 20%
Torque produced: 0% at 4mAdc and 100%
2)
Voltage signal 0
[Default setting]
Motor torque [%]
 = 100
 = 0
 = 0%
Torque produced: 0% at 0Vdc and 100%
4∼20mAdc ⇒ II terminal
4mA
20mA
 = 100%
at 20mAdc.
∼10Vdc ⇒ RR terminal
0V
10V
 = 100%
at 10Vdc.
 :VI/II reference point #1
 :VI/II reference point #2
 :RR reference point #1
 :RR reference point #2
 :RX reference point #1
 :RX reference point #2
 :BIN reference point #1
 :BIN reference point #2
[Arbitrary setting]
Motor torque [%]


★The relationship between the torque
command and the motor torque can be
changed. The  and  settings
0 and 100% correspond to currents of 0
and 20mAdc, respectively.
[Arbitrary setting]
Motor torque [%]


★The relationship between the torque
command and the motor torque can be
changed. The  and  settings
0 and 100% correspond to voltages of 0
and 10Vdc, respectively.
F-39
0


0

