Specification; Specifications By Types; Standard Specifications By Types - Toshiba TOSVERT VF-P7 Instruction Manual

Inverter for fan and pump applications
Hide thumbs Also See for TOSVERT VF-P7:
Table of Contents

Advertisement

11. Specifications by types

11. 1 Standard specifications by types

1) Standard specifications by types
Item
Voltage class
Applicable motor [kW]
Model No.
Type
Output capacity [kVA] (*1)
Output current [A]
Output voltage
Rated overload current
Dynamic braking circuit
Dynamic braking
resistor
Main
Voltage,
circuit
frequency Control
circuit(*2)
Allowable fluctuation
Protection structure
Cooling system
Coating color
EMI filter
Item
Voltage class
Applicable motor [kW]
Model No.
Type
Output capacity [kVA] (*1)
Output current [A]
Output voltage
Rated overload current
Dynamic braking circuit
Dynamic braking
resistor
Main
circuit
Voltage,
frequency Control
circuit(*2)
Allowable fluctuation
Protection structure
Cooling system
Coating color
EMI filter
(*1):
Rated output capacity indicates a value based on the condition that output voltage is 220 V in case of the 200 V class or
440 V in case of the 400 V class.
(*2):
The models of 22 kW or lower has no control power supply terminals(R0, S0). Optional control power supply is available
for those types.
(*3):
There are three openings for wiring; namely, wiring holes for main circuit input, for main circuit output and for control
circuit. After wiring is complete, close the openings properly.
(*4):
The models of 30 kW or higher have neither cover for the wiring hole that has a big aperture nor space for bending
external cables inside the unit. When a protector is installed externally, use an optional cover for the wiring hole.
(*5):
Allowable voltage variation is +/-10 % in continuously operation (100 % load).
(*6):
120 % for 1 minutes, 150 % for 0.3 second
18.5
22
2185P
2220P
28
34
73
88
3-phase 200 to 230 V (Maximum output voltage corresponds to input supply voltage.)
120% for 1 minutes, 180% for 0.5 second
Built-in dynamic braking
drive circuit
External braking resistor/ braking unit is optionally available.
Option
Voltage: +10% / -15% (*5), Frequency: +/-5%
Enclosed type (JEM1030)
IP20 (*3)
18.5
22
30
4185P
4220P
4300P
28
34
46
37
44
60
3-phase 380 to 400 V (Maximum output voltage corresponds to input supply voltage.)
120 % for 1 minutes, 180 % for 0.5 second
Built-in dynamic
braking drive circuit
External braking resistor/ braking unit is optionally available.
3-phase 380-460 V,
50/60 Hz
Option
Voltage: +10%/-15% (*5), Frequency: +/-5%
Enclosed type
(JEM1030) IP20 (*3)
K-1
Description
200 V class
30
37
VFP7–
2300P
2370P
46
55
120
144
Rating: Refer to 6.13.4.
3-phase 200-220 V, 50 Hz
3-phase 200-230 V, 60 Hz
Single phase 200-220 V, 50 Hz
Single phase 200-230 V, 60 Hz
Open type (JEM1030) IP00 (*4)
Forced-air cooling
Munsell 5Y-8/0.5
Option to be installed externally
Description
400 V class
37
45
VFP7–
4370P
4450P
55
69
72
90
Optional
Rating: Refer to 6.13.4.
3-phase 380-440 V, 50 Hz
3-phase 380-460 V, 60 Hz
Single phase 380-440 V, 50 Hz
Single phase 380-460 V, 60 Hz
Open type (JEM1030) IP00 (*4)
Forced-air cooling
Munsell 5Y-8/0.5
Option to be installed externally
45
55
2450P
2550P
69
84
180
220
Optional
55
75
4550P
4750P
4900P
84
110
110
144
90
143
180
(*6)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents