Toshiba TOSVERT VF-P7 Instruction Manual page 196

Inverter for fan and pump applications
Hide thumbs Also See for TOSVERT VF-P7:
Table of Contents

Advertisement

No.
Option name
RS-232C
communication
converter cable
RS-485 communication
converter unit
(for communication with
multiple inverters)
Communication cable
Remote control panel
Application control units
Harmonic suppression
converter
Power regeneration
converter
Option ⑩∼⑮ should be used under the condition of 9600 bps or less ().
Function, purpose.
If this unit is used to connect the inverter and a personal computer and so on with each other, data communication can
be performed between the two besides easy adjustment of parameters, saving and writing data.
               <Outline drawings with dimensions>
RJ45 connector
            (Model: RS20035)
More than one inverter can be controlled with a personal computer and so on if this unit is
used for connection between inverters and personal computer.
・Computer link: Since this unit makes it possible to connect inverters with higher-class
computer, FA computer, etc., a data communication network can be
constructed among multiple inverters.
・Communication among inverters: For the purpose of proportional operation of multiple
<Outline drawings with dimensions>
     (Model: RS4001Z)
Connection cable for connecting parameter writer, extension control panel,
RS-232C communication units, and RS-485 communication units.
Cable types: CAB0011 (1 m), CAB0013 (3 m), CAB0015 (5 m).
A frequency meter, frequency setup device, RUN/STOP (forward, reverse) switch
are built in this operation panel. (Model: CBVR-7B)
Applied control units of the AP series make various applied control possible if they
are used in combination with the inverter.
■ Proportional control panel (APP-2B)
■ Ratio setup panel (APH-7B)
■ Regulated power supply board (APV-2B)
■ Cushion starter panel (APC-2B)
■ Synchronizing control panel
(APS-2B1)
■ Synchronizing transmitter (DRR-2)
■ Remote control panel (APM-2B)
・ Higher harmonic suppressor unit improves input power-factor by suppressing
harmonic current.
・ Power regenerator unit protects the inverter from load sprung from frequent rapid
deceleration and negative torque.
For applicable models and particulars, inquire at our office.
I-8
5m
D-Sub 9pin connector
inverters, a frequency data communication network can
be constructed among multiple inverters.
25
16.5
R2.5
R2.5
8.5
30
(Model: RS4002Z)
■ Process control panel with built-in PI
controller (APJ-2B)
■ TG follower panel (APF-7B)
■ Current detection panel (APD-2B)
■ Torque control panel (APL-2B)
■ FV converter (APR-2B)
■ Loop controller (APU-2B)
100