9. 5 Optional add-on cassettes

The following add-on cassette options are prepared for the inverter VF-P7.
※It can be applied to after CPU version "V300".
■Table of optional add-on cassettes
Table of optional add-on cassettes
Option name
① Vector option
unit
② Expansion TB
option unit
③ S20 option unit
④ F10M option
unit
⑤ Device Net
option unit
⑥ Profibus
option unit
⑦ Attachment
(*1):
One can use two of Group A together with one of the Group B at a time. (Maximally 3 options)
(*2):
To use 37 kW or more models in any of conditions described below, refer to 9.7 and execute the
preparation before attachment.
i ) install the vector option unit
ii) install the S20 option unit or the F10M option unit and execute PG feedback control
(*3):
Inside ( ) indicates case of 400V class models.
■Functions of optional add-on cassettes
①Vector option unit
Function
PG feedback
Power supply for encoder
Voltage drop detection
Standby signal output
OC pre-alarm
Alarm output (Error code 0, 1,
2, 3)
P24 power supply
PG feedback output
PG line driver output
±10 V analog command power
supply
±10 V analog command input
Pulse train position control
command input
Encoder supply voltage check
Function, purpose
This option compatible to sensor
vector control is usable for speed
control and position control by the
PG feedback function.
This option provides extended
terminal functions for use.
This option provides TOSLINE-
S20 for use.
This option provides TOSLINE-
F10 for use
This option provides Device Net
for use
This option provides Profibus for
use
Attachment for fitting add-on
cassette option to the inverter.
・Consistent with line driver output encoder (Disconnection detection function is
also provided)
・ Consistent with complementary/open-collector encoder (Pulse train speed
command)
・Max. pulse freq. 60kHz(2-phase), 120kHz(single-phase), Duty: 50±10%
5 V, 6 V, 12 V, 15 V DC, 160 mA or less
Detection of voltage drop in PG power supply line
Open-collector output/sink output (30 V DC, 50 mA or less)
Approximately 1 second after the main circuit power is turned on, this terminal is
connected with COM. In an error status, circuit between this terminal and COM is
open regardless of main circuit power supply.
Open-collector output/sink output (30 V DC, 50 mA or less)
When current exceeds the limiting range, this terminal is connected with COM.
With occurrence of an error, the cause of trip is output in 4-bit binary system. Error
is detected according to the open/closed status of the circuit between the open-
collector of each terminal and COM.
+24 V DC power supply (200 mA or less) for driving external relay, etc.
Open-collector outputs of phase-A positioning pulse, phase-B positioning pulse,
phase-Z positioning pulse originating from the encoder built in the motor. (30 V DC,
50 mA or less)
Outputs phase-A positioning pulse, phase-B positioning pulse, phase-Z positioning
pulse originating from the line drive output encoder built in the motor.
Power supply for ±10 V analog voltage command. (Internal impedance: 500 Ω,
for 1 kΩ resistor)
±10 V programmable voltage command is input to this terminal.
Pulse train positioning commands for forward rotation and reverse rotation are
input to this terminal. This terminal is enabled only when it is set in the position
control mode or switched for position control.
To check encoder supply voltage.
I-10
Model
Remarks (*1)
VEC001Z
ETB001Z
TLS001Z
TLF001Z
Under
planning
Under
planning
SBP001Z For 75(132) kW or less(*3)
SBP002Z For 90(160) kW or more(*3)
Description
A
B