Toshiba TOSVERT VF-P7 Instruction Manual page 182

Inverter for fan and pump applications
Hide thumbs Also See for TOSVERT VF-P7:
Table of Contents

Advertisement

(Continued from the preceding page)
Com.No. Details of indication Key operated LED display
FE10 Past trip #1
FE11 Past trip #2
FE12 Past trip #3
FE13 Past trip #4
Cumulative
FE14
operation time
Standard monitor
mode
Note 1: When
or
Note 2: Contents of status indications of *1, *2, *3, *4 and *5 can be selected from 30 kinds of information.
Unit of current and voltage indications can be changed from % to A (amperage) and V (voltage)
and vice versa respectively.
Note 3: Indicated input voltage is DC voltage just after input voltage is rectified multiplied by 1/√2.
Note 4: Past trip is in order of 1(last)→2→3→4(oldest)
Note 5: Cumulative operation time indicates a total of actually running hours.
■Information on input terminals
Information on  input terminals and  input terminals are for the optional add-on cassette.
    
      
Note) When  is set at a number of  to  expansion TB option input terminal information (,)
indicate information of lower 8 bit terminal (B0∼B7).
⇔
⇔
⇔
⇔

MON
      

(Note 1)
key is pressed, indication changes in the status monitor mode.
Input terminal #1(F)
Input terminal #2(R)
Input terminal #3(ST)
Input terminal #4(RES)
Input terminal #5(S1)
Input terminal #6(S2)
Input terminal #7(S3)
Input terminal #8(S4)
Input terminal #9 (B8)
Input terminal #10(B9)
Input terminal #11(B10)
input terminal #12(B11)
Input terminal #13(B12)
Input terminal #14(B13)
Input terminal #15(B14)
Input terminal #16(B15)
Input terminal #9 to #16: Expansion TB option unit
H-2
Description
(Alternately blinking at intervals of 0.5
second) Past trip #1
(Alternately blinking at intervals of 0.5
second) Past trip #2
(Alternately blinking at intervals of 0.5
second) Past trip #3
(Alternately blinking at intervals of 0.5
second) Past trip #4
Indication of total (accumulated) operation
hours(Indication of 0.1 represents 10 hours.)
Running frequency indication(in operation)
:F111
:0
:F112
:1
When there is signal input
:F113
:2
:F114
:3
When there is no signal input
:F115
:4
(Blank in the upper half)
:F116
:5
:F117
:6
:F118
:6
:F119
:8
When there is signal input
:F120
:9
:F121
:10 When there is no signal input
:F122
:11 (Blank in the upper half)
:F123
:12
When there is signal input
:F124
:13
:F125
:14
When there is no signal input
:F126
:15
(Blank in the upper half)