If frequency 1
Drooping gain
Gain2= ×
100
If
≧
If|frequency after acceleration|≦ frequency 1
Gain2 = 0
If|frequency after acceleration|> frequency 1
Gain2 = Drooping gain
c) Drooping speed
Drooping speed = base frequency
Note) For this calculation, assume the base frequency to be 100 Hz if it is higher than 100 [Hz].
6.15 Function for crane/hoist
:Light-load high-speed operation
:Light-load high-speed operation switching lower limit frequency
:Light-load high-speed operation load waiting time
:Light-load high-speed operation load detection time
:Light-load high-speed operation heavy load detection time
:Switching load torque current during forward run
:Heavy load torque during acceleration in forward direction
:Heavy load torque during fixed speed in forward direction
:Switching load torque current during reverse run
:Heavy load torque during acceleration in reverse direction
:Heavy load torque during fixed speed in reverse direction
:Automatic light-load high-speed operation frequency
6.16 Commercial power/inverter switching
:Output signal selection of commercial power/inverter switching
:Commercial power/inverter switching frequency
:Inverter side switching waiting time
:Commercial power side switching waiting time
:Commercial power switching frequency holding time
・Function
The function switches between the commercial power and the inverter operation witho
ut stopping the motor in case of tripping or by sending a signal, and also to transmit
switching signals to an external sequence (MC, etc).
<|frequency after acceleration|≦frequency 2
F-31
(|freq. after acceleration| − freq.1 )
( freq.2
− freq.1 )
/ 100
Note
×Gain1×Gain2