[Monitor FM/AM/pulse output function selection]
Communication
number
0
FD00
Running frequency
1
FE02
Frequency command
2
FE03
Current
3
FE04
DC voltage
4
FE05
Output voltage
5
FE15
After-compensation frequency
6
FE16
Speed feedback (real-time value)
7
FE17
Speed feedback (1 second filter)
8
FE18
Torque
9
FE19
Torque reference
10
FE56
Internal torque reference (*1)
11
FE20
Torque current
12
FE21
Exciting current
13
FE22
PID feedback value
14
FE23
Motor overload factor (OL2 data)
15
FE24
Inverter overload factor (OL1 data)
16
FE25
PBr overload factor (PBrOL data)
17
FE28
PBr load factor (pulse duty)
18
FE29
Input power
19
FE30
Output power
20
FE31
Peak output current
21
FE32
Peak DC voltage
22
FE33
Motor counter dummy PG
23
FE34
Position pulse
24
FE35
PR input
25
FE36
VI/II input
26
FE37
RX input
27
FE38
RX2 input
28
FE39
FM output
29
FE40
AM output
30
FE57
Fixed output for meter adjustment
31
FE64
Analog output for communication
32
FE60
Acc/dec torque removal
(*1): When =7,8,9, ●/● under speed control.
(*2): Reference data
(*3): Trip frequency is displayed in another way.
For details, refer to section 5.4; [Terminal FM-related parameters].
For monitor indications, refer to section 8.2; [Set up values of monitor indication parameters].
Communication number 31(Analog output for communication) outputs analog data of FA51.
Communication
Function
unit
0.01 [Hz]
0.01 [Hz]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [Hz]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [kW]
0.01 [kW]
0.01 [%]
0.01 [%]
1 count
1count
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
0.01 [%]
Sensorless vector/vector with sensor(●: valid,−: invalid)
Monitor output
Meter output
Trip holding
selection
selection
0
(*3)
0
1
hold
1
2
hold
2
3
hold
3
4
hold
4
5
hold
5
6
hold
6
7
hold
7
8
hold
8
9
hold
9
10
hold
10
11
hold
11
12
hold
12
13
hold
13
14
hold
14
15
hold
15
16
hold
16
17
hold
17
18
hold
18
19
hold
19
20
hold
20
21
hold
21
22
hold
22
23
hold
23
24
not hold
24
25
not hold
25
26
not hold
26
27
not hold
27
28
not hold
28
29
not hold
29
hold
30
not hold
31
not hold
32
Speed
Torque
Position
V/f
control
control
control
constant
●/●
●/●
−/●
●/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
−/●
−/●
−/●
−/●
−/●
−/●
●/●
●/●
−/●
●(*2)
●/●
●/●
●/●
−/●
●/●
●/●
−/●
●(*2)
●/●
●/●
−/●
●(*2)
●/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
●/●
●/●
−/●
−/●
−/−
−/●
Reference
section
5.4