10 HIGH-LEVEL POSITIONING CONTROL

10.1.1 Data required for high-level positioning control

"High-level positioning control" is executed by setting the required items in the "block
start data" and "condition data", then starting that "block start data". Judgment about
whether execution is possible, etc., is carried out at execution using the "condition
data" designated in the "block start data".
"Block start data" can be set for each No. from 7000 to 7004 (called "block Nos."), and
up to 50 points can be set for each axis. (This data is controlled with Nos. called
"points" to distinguish it from the positioning data. For example, the 1st block start data
item is called the "1st point block start data" or "point No. 1 block start data".)
"Condition data" can be set for each No. from 7000 to 7004 (called "block Nos."), and
up to 10 data items can be set for each axis.
The " block start data" and "condition data" are set as 1 set for each block No.
The following table shows an outline of the " block start data" and "condition data"
stored in the QD75.
Setting item
Set whether to end the control after executing only the "block
Da.11 Shape
start data" of the shape itself, or continue executing the "block
start data" set in the next point.
Da.12 Start data No.
Set the "positioning data No." to be executed.
Set the method by which the positioning data set in Da.12
Da.13 Special start
instruction
will be started.
Set the conditions by which the start will be executed
Da.14 Parameter
according to the commands set in Da.13 . (Designate the
"condition data No." and "No. of repetitions".)
Setting item
Designate the "device", "buffer memory storage details", and
Da.15 Condition target
"positioning data No." elements for which the conditions are
set.
Set the judgment method carried out for the target set in
Da.16 Condition
Da.15 .
operator
Set the buffer memory address in which condition judgment is
Da.17 Address
carried out (only when the details set in Da.15 are "buffer
memory storage details").
Set the required conditions according to the details set in
Da.18 Parameter 1
Da.15 and Da.16 .
Set the required conditions according to the details set in
Da.19 Parameter 2
Da.15 and Da.16 .
10 - 3
Get other manuals https://www.bkmanuals.com
MELSEC-Q
Setting details
Setting details