12 CONTROL SUB FUNCTIONS
[2] Precautions during control
[3] Setting the speed limit function
Setting item
Pr.8
Speed limit value
JOG speed limit
Pr.31
value
Refer to Section 5.2 "List of parameters" for setting details.
Pr.8
If any axis exceeds "
the axis in excess of the speed limit value is controlled at the speed limit value.
The speeds of the other axes interpolated are suppressed depending on their
command speed ratios.
If the reference axis exceeds "
interpolation control, 2- to 4-axis fixed-feed control or 2-axis circular interpolation
control, the reference axis is controlled at the speed limit value (The speed limit
does not function on the interpolation axis side.)
To use the "speed limit function", set the "speed limit value" in the parameters
shown in the following table, and write them to the QD75.
The set details are validated after they are written to the QD75.
Setting
value
Set the speed limit value (max. speed during control).
Set the speed limit value during JOG operation (max.
speed during control). (Note that "
limit value" shall be less than or equal to "
Speed limit value".)
REMARK
Parameters are set for each axis.
It is recommended that the parameters be set whenever possible with GX
Configurator-QP. Execution by sequence program uses many sequence programs
and devices. The execution becomes complicated, and the scan times will
increase.
Get other manuals https://www.bkmanuals.com
Speed limit value" during 2- to 4-axis speed control,
Pr.8
Speed limit value" during 2- to 4-axis linear
Setting details
Pr.31
12 - 22
MELSEC-Q