5 DATA USED FOR POSITIONING CONTROL
Setting item
Cd.26
Position-speed switching
control enable flag
Cd.27
Target position change value
(New address)
Cd.28
Target position change value
(New speed)
Cd.29
Target position change
request flag
Set whether the external control signal (external command signal [CHG]: "speed-
position, position-speed switching request" is selected) is enabled or not.
When changing the target position during a positioning operation, use this data
item to specify a new positioning address.
Set a value within the following range:
mm
Pr.1
-1
(×10
µm)
-2147483648
ABS
to
+2147483647
-2147483648
INC
to
+2147483647
When changing the target position during a positioning operation, use this data
item to specify a new speed.
The speed will not change if "0" is set.
Set a value within the following range:
mm
Pr.1
×
-2
(
10
mm/min)
0 to
Setting range
2000000000
Requests a change in the target position during a positioning operation.
5 - 126
Get other manuals https://www.bkmanuals.com
Setting details
inch
degree
-5
-5
(×10
inch)
(×10
degree)
-2147483648
to
0 to 35999999
+2147483647
-2147483648
-2147483648
to
to
+2147483647
+2147483647
inch
degree
×
×
-3
-3
(
10
inch/min)
(
10
degree/min)
0 to
0 to
2000000000
2000000000
MELSEC-Q
pulse
(pulse)
-2147483648
to
+2147483647
-2147483648
to
+2147483647
pulse
(pulse/s)
0 to 1000000