15 TROUBLESHOOTING
Classification
Error
of errors
code
981
OPR direction error
OP address setting
982
error
983
OPR speed error
984
Creep speed error
985
OPR retry error
990
OPR dwell time error
Parameter
Setting for the
movement amount
991
after near-point dog
ON error
OPR acceleration
992
time selection error
OPR deceleration
993
time selection error
OPR torque limit
995
value error
Deviation counter
996
clear signal output
time setting error
Speed designation
997
during OP shift error
Error name
The set range of the OPR basic
parameter "OPR direction" is outside
the setting range.
The set range of the OPR basic
parameter "OP address" is outside
the setting range.
• The set range of the OPR basic
parameter "OPR speed" is outside
the setting range.
• The set range of the OPR basic
parameter "OPR speed" is smaller
than the bias speed at start.
• The set range of the OPR basic
parameter "Creep speed" is
outside the setting range.
• The set range of the OPR basic
parameter "Creep speed" is larger
than the OPR speed.
• The set range of the OPR basic
parameter "Creep speed" is
smaller than the bias speed at
start.
The set range of the OPR basic
parameter "OPR retry" is outside the
setting range.
The set range of the OPR detailed
parameter "OPR dwell time" is
outside the setting range.
The set range of the OPR detailed
parameter "Setting for the movement
amount after near-point dog ON" is
outside the setting range.
The set range of the OPR detailed
parameter "OPR acceleration time
selection" is outside the setting
range.
The set range of the OPR detailed
parameter "OPR deceleration time
selection" is outside the setting
range.
• The set range of the OPR detailed
parameter "OPR torque limit value"
is outside the setting range.
• The OPR detailed parameter "OPR
torque limit value" has exceeded
the detailed parameter 1 "Torque
limit setting value".
The set range of the OPR detailed
parameter "Deviation counter clear
signal output time" is outside the
setting range.
The set range of the OPR detailed
parameter "Speed designation
during OP shift" is outside the setting
range.
15 - 30
Get other manuals https://www.bkmanuals.com
Error
Operation status at error occurrence
The QD75 READY signal (X0) is not
turned ON.