Mitsubishi MELSEC QD75P User Manual page 491

Positioning module
Table of Contents

Advertisement

12 CONTROL SUB FUNCTIONS
Setting item
No. of pulses per
Pr.2
rotation
Movement amount
Pr.3
per rotation
Pr.4
Unit magnification
Refer to Section 5.2 "List of parameters" for setting details.
Calculation example
(Conditions)
Movement amount per pulse
No. of pulses per rotation
Unit magnification
(Positioning results)
Command movement amount
Actual movement amount
(Compensation amount)
5 × 10
101 × 10
3
AL'
×
=
101 × 10
AP'
12000
Movement amount per pulse
No. of pulses per rotation
Unit magnification
(e) Set the post-compensation "
Pr.3
"
Movement amount per rotation (Al')", and "
magnification (Am')" in the parameters, and write them to the QD75.
The set details are validated at the rising edge (OFF
PLC READY signal (Y0).
Setting
value
A p '
Set the post-compensation value.
A l '
Set the post-compensation value.
A m '
Set the post-compensation value.
12 - 15
Get other manuals https://www.bkmanuals.com
: 500 ( µ m/rev)
: 12000 (pulse/rev)
: 1
: 100mm
: 101mm
3
5050
101
=
=
3
12000
240
: 101 ( µ m/rev)
[Set in Pr.3 ]
: 240 (pulse/rev)
[Set in Pr.2 ]
: 1
[Set in Pr.4 ]
Pr.2
No. of pulses per rotation (Ap')",
Setting details
MELSEC-Q
Pr.4
Unit
ON) of the
Pre-compensation
value
Ap
Al
Am

Advertisement

Table of Contents
loading

Table of Contents