14 DEDICATED INSTRUCTIONS
[Control data]
Item
Device
System area
(S)+0
Complete status
(S)+1
Signal received from
(S)+2
servo amplifier
Signal transmitted to
(S)+3
servo amplifier
Status
(S)+4
(S)+5 to
System area
(S)+7
1: The data on the setting side is as follows.
• User
: Data before the execution of dedicated instructions is stored by user.
• System: Data after the execution of dedicated instruction is stored by PLC CPU.
2: Refer to Section 15.2 for error codes at abnormal completion.
[Functions]
(1) The positioning data is read from the servo amplifier capable of processing the
Servo amplifier
Setting data
The state at the time of completion is stored.
• 0
: Normal completion
• Other than 0 : Abnormal completion (error code)( 2)
The following signal states taken in from the servo
amplifier to the input module are written.
• b0: ABS data bit 0
• b1: ABS data bit 1
• b2: Transmission data READY flag
The ON/OFF states of the following data which are
calculated using the dedicated instructions by the
"signals received from the servo amplifier" and output to
the servo amplifier are stored.
• b0: Servo amplifier ON
• b1: ABS transfer mode
• b2: ABS request flag
Status of communication with servo amplifier
• 0
: Communication completed
(Set by user at communication start)
• Other than 0 : During communication (System stores)
absolute positions of the axes to be set (See below), and the values converted with
respect to a unit are stored in "
feed value" area of the QD75.
• ABRST1: Axis 1
• ABRST2: Axis 2
• ABRST3: Axis 3
• ABRST4: Axis 4
For absolute position detection system, carry out the absolute position restoration
operation each time the power is turned ON or PLC CPU is reset.
Input module
Output module
14 - 4
Get other manuals https://www.bkmanuals.com
Md.20
current feed value" and "
PLC CPU
Control data
(S)+0
(S)+1
(S)+2
(S)+3
(S)+4
(S)+5
Current value data
(S)+7
ABRST
MELSEC-Q
Setting side
Setting range
( 1)
System
b0: 0/1
b1: 0/1
User
b2: 0/1
System
0
User/system
Md.21
machine
QD75
Current
feed value
Machine
feed value