Table 27
Trunk Data Block data for PRI and PRI2 trunks (LD 14)
Prompt
Response
REQ
aaa
TYPE
xx
TN
l ch
DES
PRI
PDCA
(1) - 16
PCML
A
MU
...
...
0-511 1-4000
RTMB
...
...
xxx..x
MNDN
TGAR
0 - (1) - 31
...
...
aaaa
CLS
...
...
Procedure 30 "Configuring the DPNSS/DASS trunks with Trunk Data Block
data using LD 14" (page 98)
with Trunk Data Block data. This configuration is required for both real
(RDC) and virtual (VDC) channel types.
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
0000
Access LD 14. Enter the command:
LD 14
Enter the responses shown in
PRI and PRI2 trunks (LD 14)" (page
Description
Request (aaa = CHG, NEW)
Trunk data block.
Terminal Number for digital trunks where l=loop, ch=channel.
Designator field for trunk.
Pad category table number.
Pulse Code Modulation Law. Enter the appropriate value,
based on which companding law is being used on the system.
A = A-Law
MU = Mu-Law
Route number and Member Number.
Range is the same as that for CS 1000E system.
One seven-digit manual directory number.
Trunk Group Access Restriction.
The default value (1) automatically blocks direct access.
Class of Service.
Note: VDC configuration is not required for DASS signaling.
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Configure E1/T1 ports on a Call Server 97
Table 27 "Trunk Data Block data for
97).
—End—
describes how to configure the DPNSS trunks