6
Table 14
PRI2 loop configuration (LD 17)
Prompt
Response
REQ
CHG
TYPE
CEQU
CFN
YES
...
PRI2
loop
MG_CARD
supl sh card
Procedure 18 "Configuring DPNSS/DASS loops using LD 17" (page 79)
shows the configuration in LD 17 needed to support DPNSS loops (common
equipment parameters) on the PRI Gateway.
Procedure 18
Configuring DPNSS/DASS loops using LD 17
Step
1
2
3
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Access LD 17. Enter the command:
LD 17
Enter the responses shown in
(LD 17)" (page
79).
Description
Change existing data.
Make changes to common equipment parameters.
Common equipment.
Digital loop (2.0 Mb) (0 - 255)
The physical card for the PRI2 loop association to the PRI
Gateway.
The format is superloop, shelf, card.
For the PRI Gateway, card 1 to 8 is applicable.
Action
Log on to the CS 1000E.
Enter the command:
LOGI
System response:
USERID?
Enter the default username:
admin1 or admin2
System response:
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007