Nortel Media Gateway 1000E PRI Installation And Comissioning Manual page 84

Hide thumbs Also See for Media Gateway 1000E PRI:
Table of Contents

Advertisement

84 Configure an E1/T1 card
Procedure 21
Configuring DPNSS/DASS D-channels in the PRI Gateway using LD 17
Step
1
2
3
4
5
6
Table 18
DPNSS/DASS D-channel interface configuration (LD 17)
Prompt
Response
REQ
CHG
TYPE
ADAN
ADAN
NEW DCH xx
CTYP
DCHI
MG_CARD
supl sh card
PORT
1
...
...
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Action
Log on to the CS 1000E.
Enter the command:
LOGI
System response:
USERID?
Enter the default username:
admin1 or admin2
System response:
PASS?
Enter the default password:
0000
Access LD 17. Enter the command:
LD 17
Enter the responses shown in
interface configuration (LD 17)" (page
Description
Change existing data.
Action device and number.
Add a D-channel on logical port 0 - 15.
D-channel configuration on DCHI card Type (NTAK93AB).
The physical card for the digital loop association to the PRI
Gateway.
The format is: superloop, shelf number, card number.
Note: If using a NTAK93AB daughterboard, even card numbers
are applicable (2, 4, 6, 8). If using the onboard DPNSS/DASS,
odd and even numbers are applicable (1, 2, 3, 4, 5, 6, 7, 8).
Port number of the NTAK93AB for DPNSS/DASS D-channel.
For a DPNSS/DASS D-channel, the port is always 1.
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Table 18 "DPNSS/DASS D-channel
84).

Advertisement

Table of Contents
loading

Table of Contents