Nortel Media Gateway 1000E PRI Installation And Comissioning Manual page 153

Hide thumbs Also See for Media Gateway 1000E PRI:
Table of Contents

Advertisement

Appendix B
Media Gateway Controller system
alarms, events, and messages
The Media Gateway Controller (MGC) platform displays the messages
shown in
153). They include, for example, hardware level faults and firmware faults,
including Tones and Conference, Call Server synchronization problems.
Table 37
MGC system alarms, events, and messages
Message
Severity
MGC0000
Critical
MGC0001
Critical
MGC0002
Critical
(E002)
MGC0003
Clear
(E002)
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Table 37 "MGC system alarms, events, and messages" (page
Description
Cold start of the MGC
<supl shelf> occurred.
Reason: <Power cycle
/ Hardware watchdog
expired / User initiated/
Software error>.
Warm start of the MGC
<supl shelf> occurred.
Reason: <Normal after
cold start / Rest button
pressed / User initiated /
Software error>.
Unable to send MGC
<supl shelf> registration
request to the Call Server.
MGC <supl shelf>
registered to the Call
Server.
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Corrective action
Depending on the
reason code, contact
Nortel support.
Depending on the
reason code, contact
Nortel support.
Check IP configuration
and network
connections.
None
153
Output
(TTY, LOG,
SNMP, LED)
TTY, LOG,
SNMP
TTY, LOG,
SNMP
TTY, LOG,
SNMP, LED
TTY, LOG,
SNMP, LED

Advertisement

Table of Contents
loading

Table of Contents