D-channel configuration example
Table 19 "D-channel configuration example " (page 85)
configuration example in the PRI Gateway of two D-channel interfaces on
the same downloadable D-channel daughterboard that serves two PRI2
loops as follows:
Table 19
D-channel configuration example
Prompt
Response
REQ
CHG
TYPE
CEQU
...
200
PRI2
MG_CARD
4 0 3
...
201
PRI2
MG_CARD
4 0 4
...
TYPE
ADAN
ADAN
NEW DCH 70
CTYP
MSDL
Media Gateway 1000E PRI Gateway Installation and Commissioning
Copyright © 2007, Nortel Networks
.
Designator (up to 16 alphanumeric characters).
Digital Private Network Signaling.
Two PRI2/E1 loops (numbered 200 and 201) are configured (for
example, superloop 4 0). Each loop simulates different physical cards (3
and 4).
Two D-channel interfaces are defined to serve two different loops/spans
(200 and 201). They use the same downloadable D-channel
daughterboard (port 0 and port 1) simulated through the physical
location of card 4.
Description
New data.
Make changes to common equipment parameters.
Digital loop (2.0 Mb) number 200.
The first PRI2 loop (simulating physical card 3 on the PRI
Gateway) – superloop 4, shelf 0 (PRI Gateway), card 3.
Digital loop (2.0 Mb) number 201.
The second PRI2 loop (simulating physical card 4 on the PRI
Gateway) – superloop 4, shelf 0 (PRI Gateway), card 4.
Action device and number.
Add a D-channel interface on logical port 70.
D-channel configuration on MSDL card.
MSDL= NTBK51AA downloadable D-channel daughterboard.
Nortel Communication Server 1000
NN43041-311 01.01 Standard
Release 5.0 30 May 2007
Configure E1/T1 ports on a Call Server 85